Product Details | ROTARY SWITCH

5930-01-210-6382 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).

Part Alternates: 16SB1CF949SSM2P, 5930-01-210-6382, 01-210-6382, 5930012106382, 012106382

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 14 JUN 1985 01-210-6382

Drawings & Photos | NSN 5930-01-210-6382


Cross Reference | NSN 5930-01-210-6382

Part Number Cage Code Manufacturer
16SB1CF949SSM2P 02989 GENERAL ELECTRIC CO GE DRIVE SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-210-6382

Technical Data | NSN 5930-01-210-6382

Characteristic Specifications
STYLE DESIGNATOR 17 IN-LINE, CAM ACTUATED
OVERALL LENGTH 8.687 INCHES NOMINAL
OVERALL HEIGHT 4.500 INCHES NOMINAL
OVERALL WIDTH 4.500 INCHES NOMINAL
INDIVIDUAL SECTION QUANTITY 3
SWITCH CONTACT BASIC DESIGN NONPILE-UP NONSYMMETRICAL
CAM ACTUATED SWITCH CONTACT ARRANGEMENT 2 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED EACH SWITCH EACH SECTION PERIPHERY
CONTACT VOLTAGE RATING IN VOLTS 550.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL 115.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL 600.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL 24.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL
CONTACT LOAD CURRENT RATING 6.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL 40.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL 1.4 AMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL 6.0 AMPERES RESISTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL
SWITCH ACTUATOR INDEXING POSITION QUANTITY 2 SINGLE ACTUATOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET AND UNTHREADED HOLE SINGLE MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE SINGLE MOUNTING FACILITY
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY
FEATURES PROVIDED ACTUATOR KNOB AND CAM ACTUATED
III PRECIOUS MATERIAL SILVER
III PRECIOUS MATERIAL AND LOCATION CONTACTS SILVER

Restrictions/Controls & Freight Information | NSN 5930-01-210-6382

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:SItem contains silver
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-01-210-6382

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each