NSN 5930-01-118-2532 C93632, C9363-2, PSF100A-1.5
Product Details | PRESSURE SWITCH
5930-01-118-2532 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Part Alternates: C93632, C9363-2, PSF100A-1.5, PSF100A15, 5930-01-118-2532, 01-118-2532, 5930011182532, 011182532
Electrical and Electronic Equipment Components | Switches
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 30 AUG 1981 | 01-118-2532 | 00206 ( SWITCH, PRESSURE ) |
Cross Reference | NSN 5930-01-118-2532
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-01-118-2532
Related Products | NSN 5930-01-118-2532
Technical Data | NSN 5930-01-118-2532
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 28 RECTANGULAR |
OVERALL LENGTH | 1.750 INCHES NOMINAL |
OVERALL HEIGHT | 0.478 INCHES NOMINAL |
OVERALL WIDTH | 1.312 INCHES NOMINAL |
BODY LENGTH | 1.000 INCHES NOMINAL |
PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | 1.50 ACTUATION POINT NOMINAL INCHES OF WATER |
CONTACT VOLTAGE RATING IN VOLTS | 30.0 AC AT SEA LEVEL FIRST VOLTAGE 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE 10.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
MEDIA FOR WHICH DESIGNED | GAS |
PROOF PRESSURE | 8.00 POUNDS PER SQUARE INCH GAGE |
PRESSURE CONNECTOR TYPE | BARBED, UNTHREADED EXTERNAL ALL CONNECTIONS |
OUTSIDE DIAMETER | 0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM ALL CONNECTIONS |
TERMINAL TYPE | QUICK DISCONNECT, MALE |
MOUNTING METHOD | BASE AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.719 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.719 INCHES NOMINAL |
III PRECIOUS MATERIAL | GOLD |
III PRECIOUS MATERIAL AND LOCATION | CONTACTS GOLD |
Restrictions/Controls & Freight Information | NSN 5930-01-118-2532
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | G | Item contains gold |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 658 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5930-01-118-2532
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |