Product Details | THERMOSTATIC SWITCH

5930-01-025-9197 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: 17021-0-11204-0-130 DEGF, 170210112040130D, 17021-0-11204-0-130D, 170210112040130DEGF, 583342, 58334-2, 5930-01-025-9197, 01-025-9197, 5930010259197, 010259197

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 12 AUG 1976 01-025-9197

Drawings & Photos | NSN 5930-01-025-9197


Cross Reference | NSN 5930-01-025-9197

Part Number Cage Code Manufacturer
17021-0-11204-0-130 DEGF 73168 KIDDE TECHNOLOGIES INC DBA FENWAL SAFETY SYSTEMS
17021-0-11204-0-130D 73168 KIDDE TECHNOLOGIES INC DBA FENWAL SAFETY SYSTEMS
58334-2 82340 EDO CORPORATION DIV DEFENSE SYSTEMS
58334-2 9Y580 EDO CORPORATION DBA EDO NAVAL COMMAND AND SONAR

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-025-9197

Technical Data | NSN 5930-01-025-9197

Characteristic Specifications
STYLE DESIGNATOR 55 CYLINDRICAL
OVERALL LENGTH 5.375 INCHES MINIMUM AND 5.499 INCHES MAXIMUM
BODY DIAMETER 0.654 INCHES MINIMUM AND 0.662 INCHES MAXIMUM
BODY LENGTH 3.531 INCHES MINIMUM AND 3.693 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE 100.00 TO 400.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT SCREW
CONTACT STIMULUS RATING 130.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING 10.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE
MEDIA FOR WHICH DESIGNED GAS
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD BUSHING

Restrictions/Controls & Freight Information | NSN 5930-01-025-9197

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-01-025-9197

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each