Product Details | PRESSURE SWITCH

5930-00-960-2477 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Part Alternates: DA31, 5930-00-960-2477, 00-960-2477, 5930009602477, 009602477

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-960-2477

Drawings & Photos | NSN 5930-00-960-2477


Cross Reference | NSN 5930-00-960-2477

Part Number Cage Code Manufacturer
DA31 39709 MERCOID CORP THE
DA31 85274 DWYER INSTRUMENTS INC DIV DWYER INSTRUMENTS, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-960-2477

Technical Data | NSN 5930-00-960-2477

Characteristic Specifications
STYLE DESIGNATOR 26 CYLINDRICAL W/PORT
OVERALL LENGTH 7.250 INCHES NOMINAL
WIDTH ACROSS FLATS 0.563 INCHES NOMINAL
OVERALL HEIGHT 2.125 INCHES NOMINAL
OVERALL WIDTH 5.750 INCHES NOMINAL
PRESSURE SWITCH TYPE DIFFERENTIAL
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE 0.00 TO 150.00 ACTUATION POINT POUNDS PER SQUARE INCH AND 0.00 TO 150.00 DEACTUATION POINT POUNDS PER SQUARE INCH
CONTACT VOLTAGE RATING IN VOLTS 440.0 AC AT SEA LEVEL FIRST VOLTAGE 440.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD INLET CONNECTION

Restrictions/Controls & Freight Information | NSN 5930-00-960-2477

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information