Product Details | THERMOSTATIC SWITCH

5930-00-259-8926 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: H56A80, 17321-2-120, 18420-0-200 , 5930-00-259-8926, 00-259-8926, 5930002598926, 002598926, 173212120, 184200200

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-259-8926

Cross Reference | NSN 5930-00-259-8926

Part Number Cage Code Manufacturer
17321-2-120 73168 KIDDE TECHNOLOGIES INC DBA FENWAL SAFETY SYSTEMS
H56A80 58588 SURFACE COMBUSTION, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-259-8926

Technical Data | NSN 5930-00-259-8926

Characteristic Specifications
OVERALL LENGTH 4.500 INCHES NOMINAL
OVERALL DIAMETER 0.625 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 100.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 99.90 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS 230.0 AC AT SEA LEVEL FIRST VOLTAGE 115.0 AC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
OPERATING TEMP RATING -65.0 DEG FAHRENHEIT MINIMUM AND 1500.0 DEG FAHRENHEIT MAXIMUM
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE SCREW
MOUNTING METHOD FLANGE
SPECIAL FEATURES THREE 0.169 IN. DIA MTG HOLES SPACED 120 DEG APART ON 0.620 IN. RADIUS

Restrictions/Controls & Freight Information | NSN 5930-00-259-8926

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-00-259-8926

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each