Product Details | THERMOSTATIC SWITCH

5930-00-133-3016 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: A19AGE4, A19AGE-4, 82553, 5930-00-133-3016, 00-133-3016, 5930001333016, 001333016

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 20 DEC 1968 00-133-3016

Drawings & Photos | NSN 5930-00-133-3016


Cross Reference | NSN 5930-00-133-3016

Part Number Cage Code Manufacturer
82553 1Z473 PAKON INC DBA IMPAK DIVISION
A19AGE-4 92578 JOHNSON CONTROLS INC CONTROL PRODUCTS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-133-3016

Technical Data | NSN 5930-00-133-3016

Characteristic Specifications
STYLE DESIGNATOR 72 RECTANGULAR
OVERALL LENGTH 2.766 INCHES NOMINAL
OVERALL HEIGHT 3.312 INCHES NOMINAL
OVERALL WIDTH 1.562 INCHES NOMINAL
BODY LENGTH 2.031 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE 85.00 TO 140.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL ACTUATION POINT KNOB
CONTACT VOLTAGE RATING IN VOLTS 125.0 AC AT SEA LEVEL SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING 1.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH 72.000 INCHES NOMINAL
BULB LENGTH 2.750 INCHES NOMINAL
BULB DIAMETER 0.188 INCHES NOMINAL
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD FLUSH
MOUNTING FACILITY PATTERN FOUR POSITION DIAMOND

Restrictions/Controls & Freight Information | NSN 5930-00-133-3016

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable