NSN 5925-01-016-0400 01-016-0400, 010160400
Product Details | CIRCUIT BREAKER BOX
5925-01-016-0400 An enclosure which includes, mounts, and protects one or more circuit breakers. It is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. May include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. May include handle tie bars. It is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. For boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see SWITCH BOX; JACK BOX; TERMINAL BOX; and DISTRIBUTION BOX. For boxes designed to mount and protect but do not include circuit breakers, see CIRCUIT BREAKER BOX SUBASSEMBLY. See also INTERCONNECTING CABINET; PANEL, POWER DISTRIBUTION; JUNCTION BOX; and CABINET, ELECTRICAL EQUIPMENT.
Part Alternates: 5925-01-016-0400, 01-016-0400, 5925010160400, 010160400
Electrical and Electronic Equipment Components | Circuit Breakers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01-016-0400 | 19365 ( CIRCUIT BREAKER BOX ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5925-01-016-0400
Technical Data | NSN 5925-01-016-0400
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 6A RECTANGULAR, SURFACE MOUNTING |
OVERALL DEPTH | 5.750 INCHES NOMINAL |
OVERALL HEIGHT | 24.250 INCHES NOMINAL |
OVERALL WIDTH | 14.000 INCHES NOMINAL |
MATERIAL | STEEL |
SURFACE TREATMENT | GALVANIZED |
ENTRANCE TYPE AND QUANTITY | 8 TRIPLE CONCENTRIC KNOCKOUT AND 4 DOUBLE CONCENTRIC KNOCKOUT |
ENTRANCE DIAMETER NUMERIC DESIGNATOR | 0.500/0.750/1.000 AND 0.500/0.750 |
MOUNTING METHOD | UNTHREADED HOLE |
STANDARD MOUNTING PATTERN DESIGNATOR | 7C 4 POINT-RECTANGULAR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 12.000 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 22.000 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | ANY ACCEPTABLE |
SYSTEM FOR WHICH DESIGNED | THREE WIRE SINGLE PHASE |
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | 240.0 |
GROUND CONNECTION TYPE FOR WHICH DESIGNED | SOLID |
CIRCUIT BREAKER TYPE AND QUANTITY | 8 SINGLE POLE AND 1 DOUBLE POLE |
CIRCUIT BREAKER CURRENT RATING IN AMPS | 20.0 AND 100.0 |
FEATURES PROVIDED | COVER |
SPECIAL FEATURES | 100 AMP CIRCUIT BRAKER |
III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
III FRAGILITY FACTOR | MODERATELY RUGGED |
Restrictions/Controls & Freight Information | NSN 5925-01-016-0400
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |