NSN 5925-00-956-9598 AM122532VDC4, AM12-25-32VDC4, AM122550VDC4
Product Details | CIRCUIT BREAKER
5925-00-956-9598 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Part Alternates: AM122532VDC4, AM12-25-32VDC4, AM122550VDC4, AM12-25-50VDC4, AM12MG625A50UDCCUR, AM12MG6-25A50UDCCUR, AM12MG625A50VDC4, AM12MG6-25A50VDC4, AM12MG625A50VDCTDC4, AM12MG6-25A50VDCTDC4, CM5002111, CM50021-11, 10630082133, 10630082-133, 5925-00-956-9598, 00-956-9598, 5925009569598, 009569598
Electrical and Electronic Equipment Components | Circuit Breakers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 00-956-9598 | 00136 ( CIRCUIT BREAKER ) |
Cross Reference | NSN 5925-00-956-9598
Part Number | Cage Code | Manufacturer |
---|---|---|
10630082-133 | 18876 | U S ARMY AVIATION AND MISSILE COMMAND |
AM12-25-32VDC4 | 74193 | EATON CORP HEINEMANN PRODUCTS |
AM12-25-50VDC4 | 74193 | EATON CORP HEINEMANN PRODUCTS |
AM12MG3-25-28VDC4 | 74193 | EATON CORP HEINEMANN PRODUCTS |
AM12MG6-25A50UDCCUR | 74193 | EATON CORP HEINEMANN PRODUCTS |
AM12MG6-25A50VDC4 | 74193 | EATON CORP HEINEMANN PRODUCTS |
AM12MG6-25A50VDCTDC4 | 74193 | EATON CORP HEINEMANN PRODUCTS |
CM50021-11 | 0BXF1 | BOGUE SYSTEMS INC. |
M55629/1-106 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-C-55629/1 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-PRF-55629/1D | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5925-00-956-9598
Technical Data | NSN 5925-00-956-9598
Characteristic | Specifications |
---|---|
POLE QUANTITY | 1 |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES DC SINGLE LOCATION |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC SINGLE LOCATION |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.700 MINIMUM AND 2.800 MAXIMUM SINGLE LOCATION |
RESET METHOD | MANUAL |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BODY STYLE | 12A SINGLE POLE TYPE |
BODY LENGTH | 2.500 INCHES MINIMUM AND 2.530 INCHES MAXIMUM |
BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.930 INCHES MINIMUM AND 1.950 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.408 INCHES MINIMUM AND 2.552 INCHES MAXIMUM |
CASE MATERIAL | PLASTIC |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.138 INCHES |
THREAD QUANTITY PER INCH | 32 |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
ACTUATOR FUNCTION | TRIP W/SEPARATE RESET |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
III UNPACKAGED UNIT WEIGHT | 0.280 POUNDS |
III SPECIAL HANDLING FEATURE | MAGNETIC |
III PRECIOUS MATERIAL | SILVER |
III PRECIOUS MATERIAL AND LOCATION | TERMINALS SILVER AND NUTS SILVER AND |
Restrictions/Controls & Freight Information | NSN 5925-00-956-9598
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Category | Code | Description |
---|---|---|
No Freight Information |