Product Details | CARTRIDGE FUSE

5920-01-602-6816 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.

Part Alternates: JJS125, JJS-125, 5920-01-602-6816, 01-602-6816, 5920016026816, 016026816

Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors

Supply Group (FSG) NSN Assign. NIIN
59 02 FEB 2012 01-602-6816

Cross Reference | NSN 5920-01-602-6816

Part Number Cage Code Manufacturer
JJS-125 71400 COOPER BUSSMANN INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5920-01-602-6816

Technical Data | NSN 5920-01-602-6816

Characteristic Specifications
ERR DEFAULT 0.880 INCHES NOMINAL
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS 200000.0
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.500 INCHES NOMINAL
OVERALL LENGTH 3.250 INCHES NOMINAL
BODY STYLE TUBE TYPE
INTERRUPTION INDICATOR METHOD NO VISUAL INDICATION
MAXIMUM VOLTAGE RATING IN VOLTS 600.0 AC
TERMINAL THICKNESS 0.344 INCHES NOMINAL
CIRCUIT OVER-CURRENT INTERRUPTION TYPE NORMAL INSTANTANEOUS
FEATURES PROVIDED NONRENEWABLE FUSIBLE ELEMENT
CONTINUOUS CURRENT RATING IN AMPS 125.000

Restrictions/Controls & Freight Information | NSN 5920-01-602-6816

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information