NSN 5920-01-554-4097 1812L260, 34500670A, 34-500670A
Product Details | INCLOSED LINK FUSE
5920-01-554-4097 A fuse in which the element is inclosed in a body of other than cylindrical shape. It may include visual indication that the fusible element is severed. For cylindrical items, see FUSE, CARTRIDGE. Excludes FUSE, OPEN LINK; and FUSE LINK, ELECTRICAL.
Part Alternates: 1812L260, 34500670A, 34-500670A, 5920-01-554-4097, 01-554-4097, 5920015544097, 015544097
Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 08 AUG 2007 | 01-554-4097 | 00249 ( FUSE, INCLOSED LINK ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5920-01-554-4097
Related Products | NSN 5920-01-554-4097
Technical Data | NSN 5920-01-554-4097
Characteristic | Specifications |
---|---|
BODY STYLE | 8B LIMITER W/OUT HOLE |
OVERALL LENGTH | 0.176 INCHES NOMINAL |
TERMINAL LENGTH | 0.025 INCHES NOMINAL |
OVERALL HEIGHT | 0.090 INCHES NOMINAL |
OVERALL WIDTH | 0.124 INCHES NOMINAL |
TERMINAL WIDTH | 0.124 INCHES NOMINAL |
CONTINUOUS CURRENT RATING IN AMPS | 40.000 |
MAXIMUM VOLTAGE RATING IN VOLTS | 6.0 AC |
Restrictions/Controls & Freight Information | NSN 5920-01-554-4097
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |