Product Details | CARTRIDGE FUSE

5920-01-136-2651 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.

Part Alternates: 5920-01-136-2651, 01-136-2651, 5920011362651, 011362651

Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors

Supply Group (FSG) NSN Assign. NIIN
59 01-136-2651

Drawings & Photos | NSN 5920-01-136-2651


Cross Reference | NSN 5920-01-136-2651

Part Number Cage Code Manufacturer
17-00057-002 00724 RAYTHEON COMPANY DBA RAYTHEON
920814 21793 ASTRONICS TEST SYSTEMS INC.
CC-001 52750 ALAN INDUSTRIES INC
FM08A125V1/8A 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-F-23419/8 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-PRF-23419/8 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5920-01-136-2651

Technical Data | NSN 5920-01-136-2651

Characteristic Specifications
BODY STYLE 10A PIGTAIL TYPE
OVERALL LENGTH 0.825 INCHES NOMINAL
TERMINAL LENGTH 0.305 INCHES NOMINAL
OVERALL DIAMETER 0.086 INCHES NOMINAL
TERMINAL DIAMETER 0.025 INCHES NOMINAL
CONTINUOUS CURRENT RATING IN AMPS 0.125
MAXIMUM VOLTAGE RATING IN VOLTS 125.0 AC AND 125.0 DC
CIRCUIT OVER-CURRENT INTERRUPTION TYPE TIME DELAY
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS 12.0 200 PCT OF CURRENT RATING
INTERRUPTION INDICATOR METHOD VISIBLE ELEMENT
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS 300.0
TERMINAL SURFACE TREATMENT SILVER PLATED
FEATURES PROVIDED NONRENEWABLE FUSIBLE ELEMENT
III CASE MATERIAL GLASS
III TERMINAL MATERIAL COPPER
III FRAGILITY FACTOR MODERATELY DELICATE
III PRECIOUS MATERIAL SILVER
III PRECIOUS MATERIAL AND LOCATION TERMINAL SURFACES SILVER

Restrictions/Controls & Freight Information | NSN 5920-01-136-2651

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information