NSN 5920-01-083-0144 NOS 90, NOS90, WF1726/09-003
Product Details | CARTRIDGE FUSE
5920-01-083-0144 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.
Part Alternates: NOS 90, NOS90, WF1726/09-003, W-F-1726/9, WF172609003, WF17269, 5920-01-083-0144, 01-083-0144, 5920010830144, 010830144
Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 14 SEP 1979 | 01-083-0144 | 00248 ( FUSE, CARTRIDGE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5920-01-083-0144
Related Products | NSN 5920-01-083-0144
Technical Data | NSN 5920-01-083-0144
Characteristic | Specifications |
---|---|
BODY STYLE | 29A KNIFE BLADE TYPE |
OVERALL LENGTH | 7.820 INCHES MINIMUM AND 7.940 INCHES MAXIMUM |
TERMINAL LENGTH | 1.000 INCHES MINIMUM |
OVERALL DIAMETER | 1.440 INCHES MAXIMUM |
TERMINAL WIDTH | 0.715 INCHES MINIMUM AND 0.785 INCHES MAXIMUM |
TERMINAL THICKNESS | 0.122 INCHES MINIMUM AND 0.128 INCHES MAXIMUM |
CONTINUOUS CURRENT RATING IN AMPS | 90.000 |
MAXIMUM VOLTAGE RATING IN VOLTS | 600.0 AC AND 600.0 DC |
CIRCUIT OVER-CURRENT INTERRUPTION TYPE | NORMAL INSTANTANEOUS |
INTERRUPTION INDICATOR METHOD | OPAQUE BODY |
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |
FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |
III TERMINAL MATERIAL | COPPER |
MANUFACTURERS CODE | 81348 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | W-F-1726/9 |
MANUFACTURERS CODE | 81348 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | WF1726/09-003 |
Restrictions/Controls & Freight Information | NSN 5920-01-083-0144
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |