NSN 5915-01-158-5032 FBT/2-1783/25-5/50-28A/28A, FBT217832555028A28A, 1473161
Product Details | BAND PASS FILTER
5915-01-158-5032 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Part Alternates: FBT/2-1783/25-5/50-28A/28A, FBT217832555028A28A, 1473161, 147316-1, 5915-01-158-5032, 01-158-5032, 5915011585032, 011585032
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 25 JUL 1983 | 01-158-5032 | 00209 ( FILTER, BAND PASS ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5915-01-158-5032
Related Products | NSN 5915-01-158-5032
Technical Data | NSN 5915-01-158-5032
Characteristic | Specifications |
---|---|
REFERENCE FREQUENCY PER FUNCTION | 1.783 GIGAHERTZ BLANK |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 2.5 BLANK |
FREQUENCY BAND WIDTH PER FUNCTION | 1.7705 GIGAHERTZ BLANK AND 1.7955 GIGAHERTZ BLANK |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 BLANK |
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 1.7705 GIGAHERTZ BLANK AND 1.7955 GIGAHERTZ BLANK |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1 CONNECTOR, RECEPTACLE OUTPUT |
STYLE DESIGNATOR | 26 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 4.500 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.500 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.69 GIGAHERTZ BLANK AND 1.7705 GIGAHERTZ BLANK AND 1.7955 GIGAHERTZ BLANK AND 1.85 GIGAHERTZ BLANK |
III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 35.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK AND 1.0 MAXIMUM BLANK AND 35.0 MINIMUM BLANK |
III AVERAGE POWER RATING PER FUNCTION | 0.5 WATTS BLANK |
III INPUT TERMINAL MANUFACTURER CODE | 94987 |
III INPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
III OUTPUT TERMINAL MANUFACTURER CODE | 94987 |
III OUTPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
III VIBRATION RESISTANCE RANGE IN HERTZ | 0.02 TO 2000.00 |
III OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5915-01-158-5032
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 593 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-01-158-5032
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |