Product Details | BAND PASS FILTER

5915-01-079-3242 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).

Part Alternates: S6B120-282.5/10-0, S6B1202825100, 127576-006, 5915-01-079-3242, 01-079-3242, 5915010793242, 127576006, 010793242

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 01 JUL 1979 01-079-3242

Drawings & Photos | NSN 5915-01-079-3242


Cross Reference | NSN 5915-01-079-3242

Part Number Cage Code Manufacturer
127576-006 91417 HARRIS CORPORATION DBA GOVERNMENT COMMUNICATIONS
S6B120-282.5/10-0 50140 K&L MICROWAVE, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-079-3242

Technical Data | NSN 5915-01-079-3242

Characteristic Specifications
REFERENCE FREQUENCY PER FUNCTION 282.5 MEGAHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS 3.0 BLANK
FREQUENCY BAND WIDTH PER FUNCTION 280.00 MEGAHERTZ BLANK AND 285.00 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS BLANK
INPUT IMPEDANCE PER FUNCTION W/LOAD 50.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT 50.0 OHMS BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION 1.5 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION 280.0 MEGAHERTZ BLANK AND 285.0 MEGAHERTZ BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 1 CONNECTOR, RECEPTACLE OUTPUT
STYLE DESIGNATOR 26 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 4.600 INCHES NOMINAL
BODY OUTSIDE DIAMETER 0.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 TERMINAL
III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION 50.00 MEGAHERTZ BLANK AND 280.00 MEGAHERTZ BLANK AND 285.00 MEGAHERTZ BLANK AND 287.50 MEGAHERTZ BLANK
III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS 30.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 3.0 MAXIMUM BLANK AND 30.0 MINIMUM BLANK
III AVERAGE POWER RATING PER FUNCTION 18.0 WATTS BLANK
III OPERATING TEMP RANGE 0.0 TO 60.0 DEG CELSIUS
III BODY MATERIAL METAL

Restrictions/Controls & Freight Information | NSN 5915-01-079-3242

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 593 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-079-3242

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative