NSN 5915-00-408-1431 CC039711, CC0397-11, SMC35760711
Product Details | BAND PASS FILTER
5915-00-408-1431 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Part Alternates: CC039711, CC0397-11, SMC35760711, SM-C-357607-11, FL1013012A, FL10130-12A, 039711, 0397-11, 21082812, 21-0828-12, 5915-00-408-1431, 00-408-1431, 5915004081431, 004081431
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 13 JUL 1970 | 00-408-1431 | 00209 ( FILTER, BAND PASS ) |
Cross Reference | NSN 5915-00-408-1431
Part Number | Cage Code | Manufacturer |
---|---|---|
0397-11 | 32840 | CONOLOG CORPORATION DBA INIVEN |
21-0828-12 | 99480 | BUNDY ELECTRONICS DIV OF COVINGTON CORP |
CC0397-11 | 32840 | CONOLOG CORPORATION DBA INIVEN |
FL10130-12A | 10241 | TELEPHONE SYSTEMS/COMMUNICATIONS |
SM-C-357607-11 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5915-00-408-1431
Related Products | NSN 5915-00-408-1431
Technical Data | NSN 5915-00-408-1431
Characteristic | Specifications |
---|---|
REFERENCE FREQUENCY PER FUNCTION | 2.1 KILOHERTZ BLANK |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 BLANK |
FREQUENCY BAND WIDTH PER FUNCTION | 2.040 KILOHERTZ BLANK AND 2.210 KILOHERTZ BLANK |
SOURCE IMPEDANCE RATING PER FUNCTION | 600.0 OHMS BLANK |
LOAD IMPEDANCE PER FUNCTION | 600.0 OHMS BLANK |
INCLOSURE TYPE | HERMETICALLY SEALED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE INPUT-OUTPUT |
STYLE DESIGNATOR | 2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
OVERALL HEIGHT | 6.438 INCHES NOMINAL |
BODY LENGTH | 1.500 INCHES NOMINAL |
BODY HEIGHT | 6.188 INCHES NOMINAL |
BODY WIDTH | 1.500 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN |
III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.955 KILOHERTZ BLANK AND 2.125 KILOHERTZ BLANK AND 2.210 KILOHERTZ BLANK AND 2.295 KILOHERTZ BLANK |
III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK |
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
III OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5915-00-408-1431
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 593 | unknown |
Originating Activity Code | HH | Navy ICP Mechanicsburg, PA 17055-0788 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-408-1431
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |