NSN 5915-00-405-4607 SMC501105, SM-C-501105, 398439
Product Details | BAND PASS FILTER
5915-00-405-4607 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Part Alternates: SMC501105, SM-C-501105, 398439, 415701, 5915-00-405-4607, 00-405-4607, 5915004054607, 004054607
Electrical and Electronic Equipment Components | Filters and Networks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 14 APR 1971 | 00-405-4607 | 00209 ( FILTER, BAND PASS ) |
Demand History | NSN 5915-00-405-4607
Part Number | Request Date | QTY | Origin |
---|---|---|---|
SMC501105 | 2011-08-214 | 3 | United States |
Cross Reference | NSN 5915-00-405-4607
Part Number | Cage Code | Manufacturer |
---|---|---|
398439 | 80045 | L-3 COMMUNICATIONS CINCINNATI ELECTRONICS CORPORATION |
415701 | 53342 | OPT INDUSTRIES INC DIV OF ELECTRONIKA INC |
SM-C-501105 | 12436 | BAE SYSTEMS NATIONAL SECURITY SOLUTIONS INC. |
SM-C-501105 | 18212 | AMERICAN TRANS-COIL CORP DBA A T C |
SM-C-501105 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5915-00-405-4607
Related Products | NSN 5915-00-405-4607
Technical Data | NSN 5915-00-405-4607
Characteristic | Specifications |
---|---|
REFERENCE FREQUENCY PER FUNCTION | 7.1 MEGAHERTZ BLANK |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.0 BLANK |
FREQUENCY BAND WIDTH PER FUNCTION | 7.0987 MEGAHERTZ BLANK AND 7.1022 MEGAHERTZ BLANK |
INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS BLANK |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 600.0 OHMS BLANK |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT 1 PIN OUTPUT 1 PIN GROUND |
STYLE DESIGNATOR | 2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
OVERALL HEIGHT | 1.022 INCHES MAXIMUM |
BODY LENGTH | 1.510 INCHES MAXIMUM |
BODY HEIGHT | 0.760 INCHES MAXIMUM |
BODY WIDTH | 0.875 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.000 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.375 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.112 INCHES |
III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 7.0913 MEGAHERTZ BLANK AND 7.0987 MEGAHERTZ BLANK AND 7.1022 MEGAHERTZ BLANK AND 7.1093 MEGAHERTZ BLANK |
III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 70.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK AND 1.0 MAXIMUM BLANK AND 70.0 MINIMUM BLANK |
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CRYSTAL BLANK |
III OPERATING TEMP RANGE | -40.0 TO 80.0 DEG CELSIUS |
III BODY MATERIAL | METAL |
III BODY SURFACE TREATMENT | TIN |
Restrictions/Controls & Freight Information | NSN 5915-00-405-4607
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 593 | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-405-4607
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |