Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-01-270-3538 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 8141H052R2G161F, 8141-H052R2G-161F, 917AS63295, 917AS6329-5, 5910-01-270-3538, 01-270-3538, 5910012703538, 012703538

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 05 JAN 1988 01-270-3538

Drawings & Photos | NSN 5910-01-270-3538


Cross Reference | NSN 5910-01-270-3538

Part Number Cage Code Manufacturer
8141-H052R2G-161F 18796 MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
917AS6329-5 30003 NAVAL AIR SYSTEMS COMMAND

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-270-3538

Technical Data | NSN 5910-01-270-3538

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 160.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -1.00 TO 1.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 50.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS -220.0 SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -30.0 TO 30.0 SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.400 INCHES MAXIMUM
BODY WIDTH 0.400 INCHES MAXIMUM
BODY HEIGHT 0.100 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES MINIMUM
TERMINAL DIAMETER 0.016 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.200 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 7500.0 MEGOHMS
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 0.400 INCHES MAXIMUM
III INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 1000.0 MEGOHMS
(NON-CORE DATA) OVERALL HEIGHT 0.100 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 0.400 INCHES MAXIMUM

Restrictions/Controls & Freight Information | NSN 5910-01-270-3538

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-01-270-3538

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each