Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-01-156-8992 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: MR065A223GAA, MR065A223GHA, C062G223G2G5CA, 9020972, 902097-2, 5910-01-156-8992, 01-156-8992, 5910011568992, 011568992

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 27 JUN 1983 01-156-8992

Drawings & Photos | NSN 5910-01-156-8992


Cross Reference | NSN 5910-01-156-8992

Part Number Cage Code Manufacturer
902097-2 06481 NORTHROP GRUMMAN SYSTEMS CORPORATION
902097-2 96095 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS
C062G223G2G5CA 31433 KEMET ELECTRONICS CORPORATION DBA KEMET
MR065A223GAA S9915 AVX-AVIO EXCELENTE S.A. DE C.V.
MR065A223GHA 04222 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-156-8992

Technical Data | NSN 5910-01-156-8992

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 22000.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -2.00 TO 2.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 50.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 0.0 SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -30.0 TO 30.0 SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.290 INCHES NOMINAL
BODY WIDTH 0.290 INCHES NOMINAL
BODY HEIGHT 0.090 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.250 INCHES MINIMUM
TERMINAL DIAMETER 0.025 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.200 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 100000.0 MEGOHMS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 0.1500
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 0.290 INCHES NOMINAL
III INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 10000.0 MEGOHMS
(NON-CORE DATA) OVERALL HEIGHT 0.090 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 0.290 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-01-156-8992

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-01-156-8992

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each