Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-01-100-4787 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: M39014/02-0250, M39014/02-1250, M39014020250, M39014021250, MIL-C-39014/2, MILC390142, 5910-01-100-4787, 01-100-4787, 5910011004787, 011004787

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 07-SEP-80 01-100-4787

Drawings & Photos | NSN 5910-01-100-4787


Cross Reference | NSN 5910-01-100-4787

Part Number Cage Code Manufacturer
0410026-001 05157 COHU, INC. DBA COHU ELECTRONIC'S DIVISION
283-0360-00 80009 TEKTRONIX, INC. DBA TEKTRONIX
532138-8 96214 RAYTHEON COMPANY DBA RAYTHEON
538137-289 96214 RAYTHEON COMPANY DBA RAYTHEON
6L.5224.005.00-485398 D0327 SELEX COMMUNICATIONS GMBH
8133L9BREV5U332K 72982 ERIE SPECIALTY PRODUCTS INC
833019-0289 65597 THALES DEFENSE & SECURITY, INC.
833019-0330 65597 THALES DEFENSE & SECURITY, INC.
880623 07342 NAI TECHNOLOGIES INC
913-3995-000 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
913-9008-470 95105 ROCKWELL COLLINS, INC. DIV GOVERNMENT SYSTEMS - DALLAS
947249-1249 06481 NORTHROP GRUMMAN SYSTEMS CORPORATION
997009-1329 06481 NORTHROP GRUMMAN SYSTEMS CORPORATION
CK06BK332K 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CK06BX332K 00656 AEROVOX CORP.
CK06BX332M 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CK06CW332K 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CKR06BX332K 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CKR06BX332KP 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CKR06BX332KR 00656 AEROVOX CORP.
CKR06BX332KR 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CKR06BX332KS 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014-02-0289 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014-02-0330 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014-02-1210 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-0036 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-0250 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-0369 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-0370 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-1209 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-1240 39014 TORONTO MEDICAL CORP LTD
M39014/02-1249 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-1250 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-1289 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-1290 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-1329 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/02-1369 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39014/2-1249 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-39014/2 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-PRF-39014/2 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MILC11015 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-100-4787

Technical Data | NSN 5910-01-100-4787

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 3300.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -20.00 TO 20.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 200.0 DC SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE -25.0 TO 15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.290 INCHES NOMINAL
BODY WIDTH 0.290 INCHES NOMINAL
BODY HEIGHT 0.090 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.250 INCHES MINIMUM
TERMINAL DIAMETER 0.025 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.200 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 100000.0 MEGOHMS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 2.5000
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.1000
TEST DATA DOCUMENT 81349-MIL-C-39014/2 SPECIFICATION
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-39014/2
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39014/02-1250

Restrictions/Controls & Freight Information | NSN 5910-01-100-4787

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information