5910-01-052-9124 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 5020EM50RD104K, 5910-01-052-9124, 01-052-9124, 5910010529124, 010529124

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01-052-9124

Drawings & Photos | NSN 5910-01-052-9124


Cross Reference | NSN 5910-01-052-9124

Part Number Cage Code Manufacturer
0160-5765 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP
07790 25420 MOTOROLA/CODEX CORP SUB OF MOTOROLA INC
116692-055 89022 TDK-LAMBDA AMERICAS INC. DIV HIGH POWER DIVISION
179035-0015 64415 SELEX ES INC.
1CZ5U104X0050C4 56289 SPRAGUE ELECTRIC CO WORLD HQS
200-100-WR5-104K 51642 CENTRE CAPACITOR INC
200-100-X7R-104K 51642 CENTRE CAPACITOR INC
2223220-1 19315 HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS FORMER BENDIX NAVIGATION AND
5020EM50RD104K 20932 ILLINOIS TOOL WORKS INC EMCON DIV
CW20A104K 16546 MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
CY20C104M 99942 N A P SMD TECHNOLOGY INC
CY20C104P 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
SR201C104KAA 04222 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS
VP32BY104KB 95275 VITRAMON INC PO BOX 544 BRIDGEPORT CT 06601

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-052-9124

Technical Data | NSN 5910-01-052-9124

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 0.100 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 50.0 DC SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE -15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.150 INCHES MAXIMUM
BODY WIDTH 0.150 INCHES MAXIMUM
BODY HEIGHT 0.100 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES MINIMUM
TERMINAL DIAMETER 0.020 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.100 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 2500.0 MEGOHM-MICROFARADS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 2.5000
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 0.150 INCHES MAXIMUM
(NON-CORE DATA) OVERALL HEIGHT 0.100 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 0.275 INCHES MAXIMUM