Product Details | GAS DIELECTRIC FIXED CAPACITOR

5910-00-957-6217 A capacitor, whose capacitance value cannot be adjusted or varied. It may be a single unit, or consist of two or more fixed untis which cannot be separated. Its dielectric may be either gas or vacuum.

Part Alternates: CY125S, CY-1-25S, Y117N478, Y1-17N478, 9190111000, 919-0111-000, 919011100REVA, 919-0111-00REVA, 9190262010, 919-0262-010, 9190262060, 919-0262-060, 5910-00-957-6217, 00-957-6217, 5910009576217, 009576217

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 13 MAY 1966 00-957-6217

Drawings & Photos | NSN 5910-00-957-6217


Cross Reference | NSN 5910-00-957-6217

Part Number Cage Code Manufacturer
919-0111-000 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
919-0111-00REVA 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
919-0262-010 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
919-0262-060 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
919-0262-060 95105 ROCKWELL COLLINS, INC. DIV GOVERNMENT SYSTEMS - DALLAS
CY-1-25S 73905 JENNINGS TECHNOLOGY COMPANY LLC DBA JENNINGS
Y1-17N478 73905 JENNINGS TECHNOLOGY COMPANY LLC DBA JENNINGS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-957-6217

Technical Data | NSN 5910-00-957-6217

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 1.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 25000.0 AC-PEAK SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.750 INCHES MAXIMUM
BODY LENGTH 2.500 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
CONTINUOUS CURRENT RATING IN AMPS 9.0
TERMINAL TYPE AND QUANTITY 2 FERRULE
TERMINAL LENGTH 0.375 INCHES NOMINAL
TERMINAL DIAMETER 0.344 INCHES NOMINAL
CASE MATERIAL CERAMIC
FEATURES PROVIDED HERMETICALLY SEALED CASE
(NON-CORE DATA) OVERALL LENGTH 3.250 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-00-957-6217

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code HH Navy ICP
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-957-6217

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each