Product Details | GLASS DIELECTRIC VARIABLE CAPACITOR

5910-00-329-5749 A capacitor whose capacitance value is controlled by a mechanical means which effects a continuous variation of its capacitance. It includes items consisting of two or more variable capacitors which are inseparable.

Part Alternates: 885C906P1, TP9C, 5910-00-329-5749, 00-329-5749, 5910003295749, 003295749

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 09 DEC 1973 00-329-5749

Drawings & Photos | NSN 5910-00-329-5749


Cross Reference | NSN 5910-00-329-5749

Part Number Cage Code Manufacturer
885C906P1 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE
TP9C 18736 VOLTRONICS CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-329-5749

Technical Data | NSN 5910-00-329-5749

Characteristic Specifications
CAPACITANCE RANGE IN PICOFARADS 0.8 TO 8.5 SINGLE SECTION
NONDERATED VOLTAGE RATING AND TYPE 750.0 DC CONTINUOUS SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
TEMP COEFFICIENT OF CAPACITANCE RANGE IN PPM PER DEG CELSIUS -50.0 TO 50.0 SINGLE SECTION
BODY STYLE 27 PISTON
OVERALL LENGTH 0.732 INCHES MAXIMUM
BODY LENGTH 0.577 INCHES NOMINAL
OVERALL DIAMETER 0.312 INCHES NOMINAL
INCLOSURE TYPE ENCASED
ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY 1 SLOTTED SCREW
ADJUSTMENT DEVICE TORQUE 1.000 INCH-OUNCES MINIMUM AND 6.000 INCH-OUNCES MAXIMUM
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.440 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER 0.235 INCHES MINIMUM AND 0.281 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 TERMINAL
III INSULATION DC RESISTANCE AT 25 DEG CELSIUS 1000.0 KILOHMS
III QUALITY FACTOR AT 25 DEG CELSIUS 650.0

Restrictions/Controls & Freight Information | NSN 5910-00-329-5749

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-329-5749

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each