NSN 5910-00-114-1079 M23269052091, M23269-05-2091, MILC232695
Product Details | GLASS DIELECTRIC FIXED CAPACITOR
5910-00-114-1079 A capacitor, whose capacitance value cannot be adjusted or varied, having a glass (silicas) or glass like substance (e.g., porcelain, vitreous enamel) as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Part Alternates: M23269052091, M23269-05-2091, MILC232695, MILC23269-5, 5910-00-114-1079, 00-114-1079, 5910001141079, 001141079
Electrical and Electronic Equipment Components | Capacitors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 13 JUL 1973 | 00-114-1079 | 00004 ( CAPACITOR, FIXED, GLASS DIELECTRIC ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5910-00-114-1079
Related Products | NSN 5910-00-114-1079
Technical Data | NSN 5910-00-114-1079
Characteristic | Specifications |
---|---|
CAPACITANCE VALUE PER SECTION | 100.000 PICOFARADS SINGLE SECTION |
TOLERANCE RANGE PER SECTION | -1.00 TO 1.00 PERCENT SINGLE SECTION |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 105.0 SINGLE SECTION |
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -25.0 TO 25.0 SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
BODY STYLE | 29A W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE |
BODY LENGTH | 0.375 INCHES NOMINAL |
BODY WIDTH | 0.188 INCHES NOMINAL |
BODY HEIGHT | 0.156 INCHES NOMINAL |
SCHEMATIC DIAGRAM DESIGNATOR | 1C NO COMMON OR GROUNDED ELECTRODE(S) |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TERMINAL LENGTH | 1.125 INCHES MINIMUM |
TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.300 INCHES NOMINAL |
CASE MATERIAL | GLASS |
INSULATION RESISTANCE AT REFERENCE TEMP | 500000.0 MEGOHMS |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.1000 |
RELIABILITY INDICATOR | ESTABLISHED |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 2.0000 |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
TEST DATA DOCUMENT | 81349-MIL-C-23269 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-C-23269/5 GOVERNMENT SPECIFICATION |
III MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C |
(NON-CORE DATA) OVERALL LENGTH | 0.375 INCHES NOMINAL |
III INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 100000.0 MEGOHMS |
(NON-CORE DATA) OVERALL HEIGHT | 0.156 INCHES NOMINAL |
(NON-CORE DATA) OVERALL WIDTH | 0.188 INCHES NOMINAL |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILC23269-5 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M23269-05-2091 |
Restrictions/Controls & Freight Information | NSN 5910-00-114-1079
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5910-00-114-1079
Category | Code | Description |
---|---|---|
Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |