Product Details | PRE WIRE WOUND VARIABLE RESISTOR

5905-01-577-1787 A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity) of the output is equal to or less than plus or munus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE, For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION.

Part Alternates: PRV6 CK 1M 10%, PRV6CK1M10, 5905-01-577-1787, 01-577-1787, 5905015771787, 015771787

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 27 AUG 2009 01-577-1787

Demand History | NSN 5905-01-577-1787

Part Number Request Date QTY Origin
5905-01-577-1787 2019-08-214 3 MANUAL

Cross Reference | NSN 5905-01-577-1787

Part Number Cage Code Manufacturer
PRV6 CK 1M 10% 1P1R3 VISHAY FOIL RESISTORS VISHAY AMERICAS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-577-1787

Technical Data | NSN 5905-01-577-1787

Characteristic Specifications
END ITEM IDENTIFICATION K-SAM (KOREA SURFACE-TO-AIR MISSILE)

Restrictions/Controls & Freight Information | NSN 5905-01-577-1787

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information