NSN 5905-01-552-1487 876193, 01-552-1487, 015521487
Product Details | NONPRECISION WIRE WOUND VARIABLE RESISTOR
5905-01-552-1487 A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
Part Alternates: 876193, 5905-01-552-1487, 01-552-1487, 5905015521487, 015521487
Electrical and Electronic Equipment Components | Resistors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 06 JUN 2007 | 01-552-1487 | 37406 ( RESISTOR, VARIABLE, WIRE WOUND, NONPRECISION ) |
Cross Reference | NSN 5905-01-552-1487
Part Number | Cage Code | Manufacturer |
---|---|---|
876193 | 89536 | FLUKE CORPORATION |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5905-01-552-1487
Technical Data | NSN 5905-01-552-1487
Characteristic | Specifications |
---|---|
III END ITEM IDENTIFICATION | FLUKE 77 SERIES III MULTIMETER |
Restrictions/Controls & Freight Information | NSN 5905-01-552-1487
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |