Product Details | COMPOSITION FIXED RESISTOR

5905-01-550-7812 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of a mixture of carbon, an insulating material, and suitable binders, either molded together or applied as a thin layer of conducting material on an insulated form. The opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the item itself. See also ATTENUATOR, FIXED; RESISTOR, FIXED, FILM; and RESISTOR, THERMAL. Excludes SUPPRESSOR, IGNITION INTERFERENCE.

Part Alternates: MCF 0.25W 10K, MCF025W10K, 5905-01-550-7812, 01-550-7812, 5905015507812, 015507812

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 27 APR 2007 01-550-7812

Drawings & Photos | NSN 5905-01-550-7812


Cross Reference | NSN 5905-01-550-7812

Part Number Cage Code Manufacturer
MCF 0.25W 10K 0VY29 MULTICOMP INC DBA LABELONCE CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-550-7812

Technical Data | NSN 5905-01-550-7812

Characteristic Specifications
ELECTRICAL RESISTANCE 10.000 KILOHMS
RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000
POWER DISSIPATION RATING IN WATTS 0.250 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER -55.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 155.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 14 AXIAL TERMINAL EACH END
BODY DIAMETER 6.8 MILLIMETERS MAXIMUM
BODY LENGTH 2.5 MILLIMETERS MAXIMUM
TERMINAL TYPE WIRE LEAD
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 28.0 MILLIMETERS NOMINAL
TERMINAL WIDTH WOUND 0.5 MILLIMETERS NOMINAL ,NONPRECISION

Restrictions/Controls & Freight Information | NSN 5905-01-550-7812

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information