Product Details | PRECISION WIRE WOUND VARIABLE RESISTOR

5905-01-167-8455 A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity) of the output is equal to or less than plus or munus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE, For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION.

Part Alternates: 1152343, 115-2343, 5905-01-167-8455, 01-167-8455, 5905011678455, 011678455

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 07 DEC 1983 01-167-8455

Drawings & Photos | NSN 5905-01-167-8455


Cross Reference | NSN 5905-01-167-8455

Part Number Cage Code Manufacturer
115-2343 85604 KEPCO, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-167-8455

Technical Data | NSN 5905-01-167-8455

Characteristic Specifications
SECTION QUANTITY 1
ELECTRICAL RESISTANCE PER SECTION 1.0 KILOHMS SINGLE SECTION
RESISTANCE TOLERANCE PER SECTION IN PERCENT -5.0 TO 5.0 SINGLE SECTION
FUNCTION CONFORMITY PER SECTION SINGLE SECTION INDEPENDENT LINEARITY
FUNCTION CHARACTERISTIC PER SECTION SINGLE SECTION LINEAR
FUNCTION CONFORMITY TOLERANCE PER SECTION -0.20 TO 0.20 SINGLE SECTION
MAXIMUM STARTING TORQUE 5.00 INCH-OUNCES
MAXIMUM RUNNING TORQUE 5.00 INCH-OUNCES
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS -70.0 TO 70.0 SINGLE SECTION
POWER DISSIPATION RATING PER SECTION IN WATTS 1.0 FREE AIR SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER 70.0 SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER 150.0 SINGLE SECTION
BODY STYLE 26B RECTANGULAR W/MOUNTING HOLES/SLOTS
BODY LENGTH 1.250 INCHES NOMINAL
BODY WIDTH 0.190 INCHES NOMINAL
BODY HEIGHT 0.300 INCHES MINIMUM AND 0.330 INCHES MAXIMUM
LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS 0.700 INCHES NOMINAL
ACTUATOR TYPE SINGLE SHAFT
SHAFT STYLE 3C ROUND, SLOTTED
SHAFT DIAMETER 0.100 INCHES MINIMUM AND 0.130 INCHES MAXIMUM
SHAFT LENGTH 0.036 INCHES MINIMUM AND 0.080 INCHES MAXIMUM
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG 7918.0 MINIMUM AND 7922.0 MAXIMUM
ACTUATOR TRAVEL CONTROL FEATURE CLUTCH
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION 7918.0 MINIMUM AND 7922.0 MAXIMUM
MOUNTING METHOD UNTHREADED HOLE
MOUNTING FACILITY QUANTITY 2
MOUNTING HOLE DIAMETER 0.093 INCHES NOMINAL
FEATURES PROVIDED HUMIDITY PROOF
TERMINAL TYPE AND QUANTITY 3 PIN
CENTER TO CENTER DISTANCE BETWEEN TERMINALS 0.900 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL 0.700 INCHES MINIMUM AND 0.900 INCHES MAXIMUM
TERMINAL LENGTH 0.470 INCHES MINIMUM AND 0.530 INCHES MAXIMUM
TERMINAL LOCATION LOWER ADJACENT SIDE SINGLE ROW
RELIABILITY INDICATOR NOT ESTABLISHED
III UNPACKAGED UNIT WEIGHT 2.8 GRAMS
III CUBIC MEASURE 0.078 CUBIC INCHES
III FRAGILITY FACTOR MODERATELY RUGGED

Restrictions/Controls & Freight Information | NSN 5905-01-167-8455

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-01-167-8455

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each