NSN 5905-01-131-0174 ALSR1075, ALSR-10-75, 01-131-0174
Product Details | INDUCTIVE WIRE WOUND FIXED RESISTOR
5905-01-131-0174 INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.
Part Alternates: ALSR1075, ALSR-10-75, 5905-01-131-0174, 01-131-0174, 5905011310174, 011310174
Electrical and Electronic Equipment Components | Resistors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 02 MAY 1982 | 01-131-0174 | 37403 ( RESISTOR, FIXED, WIRE WOUND, INDUCTIVE ) |
Cross Reference | NSN 5905-01-131-0174
Part Number | Cage Code | Manufacturer |
---|---|---|
ALSR-10-75 | 30487 | HUNTINGTON ELECTRIC INC DBA CENTRAL RESISTOR DIVISION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5905-01-131-0174
Related Products | NSN 5905-01-131-0174
Technical Data | NSN 5905-01-131-0174
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 75.000 OHMS |
RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
POWER DISSIPATION RATING IN WATTS | 10.000 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | NOT RATED |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | NOT RATED |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | 14 AXIAL TERMINAL EACH END |
BODY DIAMETER | 0.312 INCHES NOMINAL |
BODY LENGTH | 1.800 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5905-01-131-0174
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 093490 | BOLT/NUT/SCREW/CLIPS/FASTENER/ETC |
Less than car load rating | ||
Less than truck load rating | U | 50.0 |
Water commodity Code | 713 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |