NSN 5905-01-103-7862 MIL-R-39009/1, MILR390091, RER60F1R74M
Product Details | INDUCTIVE WIRE WOUND FIXED RESISTOR
5905-01-103-7862 INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.
Part Alternates: MIL-R-39009/1, MILR390091, RER60F1R74M, RER60F1R74R, 5905-01-103-7862, 01-103-7862, 5905011037862, 011037862
Electrical and Electronic Equipment Components | Resistors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 20 NOV 1980 | 01-103-7862 | 37403 ( RESISTOR, FIXED, WIRE WOUND, INDUCTIVE ) |
Demand History | NSN 5905-01-103-7862
Part Number | Request Date | QTY | Origin |
---|---|---|---|
MILR390091 | 2007-10-290 | 5 | Turkey |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5905-01-103-7862
Related Products | NSN 5905-01-103-7862
Technical Data | NSN 5905-01-103-7862
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 1.740 OHMS |
RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
INCLOSURE METHOD | ENCASED |
STYLE DESIGNATOR | 148 AXIAL TERMINAL |
BODY LENGTH | 0.538 INCHES MINIMUM AND 0.662 INCHES MAXIMUM |
BODY WIDTH | 0.272 INCHES MINIMUM AND 0.396 INCHES MAXIMUM |
BODY HEIGHT | 0.289 INCHES MINIMUM AND 0.351 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.434 INCHES MINIMUM AND 0.454 INCHES MAXIMUM |
MOUNTING HOLE SIZE | 0.088 INCHES MINIMUM AND 0.098 INCHES MAXIMUM |
TERMINAL TYPE | TAB, SOLDER LUG |
RELIABILITY INDICATOR | ESTABLISHED |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
TERMINAL LENGTH | 0.204 INCHES MINIMUM AND 0.328 INCHES MAXIMUM |
TERMINAL WIDTH | 0.085 INCHES MINIMUM |
TEST DATA DOCUMENT | 81349-MIL-R-39009 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39009/1 GOVERNMENT SPECIFICATION |
III UNPACKAGED UNIT WEIGHT | 3.0 GRAMS |
(NON-CORE DATA) CUBIC MEASURE | 0.064 CUBIC INCHES |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-39009/1 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RER60F1R74R |
Restrictions/Controls & Freight Information | NSN 5905-01-103-7862
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 062960 | REOSTATS/PARTS NOI |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5905-01-103-7862
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |