Product Details | INDUCTIVE WIRE WOUND FIXED RESISTOR

5905-01-091-9866 INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.

Part Alternates: R22335, R223-3-5, W2230HMS5PCT, W22-30HMS5PCT, 5905-01-091-9866, 01-091-9866, 5905010919866, 010919866

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 17 MAR 1980 01-091-9866

Drawings & Photos | NSN 5905-01-091-9866


Cross Reference | NSN 5905-01-091-9866

Part Number Cage Code Manufacturer
R223-3-5 K1182 THALES UK LIMITED DBA THALES UK LTDTRAINING AND SIMULATION
W22-30HMS5PCT U1395 WELWYN COMPONENTS LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-091-9866

Technical Data | NSN 5905-01-091-9866

Characteristic Specifications
ELECTRICAL RESISTANCE 3.000 OHMS
RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000
POWER DISSIPATION RATING IN WATTS 8.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 70.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 350.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -75.0 TO 75.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 350.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 14 AXIAL TERMINAL EACH END
BODY DIAMETER 0.313 INCHES NOMINAL
BODY LENGTH 0.875 INCHES NOMINAL
TERMINAL TYPE WIRE LEAD
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 1.500 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5905-01-091-9866

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 093490 BOLT/NUT/SCREW/CLIPS/FASTENER/ETC
Less than car load rating
Less than truck load rating U 50.0
Water commodity Code 713 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-01-091-9866

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each