Product Details | NONINDUCTIVE WIRE WOUND FIXED RESISTOR

5905-01-082-1846 INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.

Part Alternates: KP1019000F, KP101-9000F, PC89000F, PC8-9000F, 08113113, 0811-3113, 1350-1/8-901-F, 135018901F, 40609000F, 4060-9000F, 4159000F, 415-9000F, 5905-01-082-1846, 01-082-1846, 5905010821846, 010821846

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 28 AUG 1979 01-082-1846

Drawings & Photos | NSN 5905-01-082-1846


Cross Reference | NSN 5905-01-082-1846

Part Number Cage Code Manufacturer
0811-3113 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
0811-3113 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP
1350-1/8-901-F 58880 MEGGITT (NEW HAMPSHIRE), INC
4060-9000F 54294 SHALLCROSS INC
415-9000F 20940 MICRO-OHM CORPORATION
KP101-9000F 19587 KELVIN INDUSTRIES INC
PC8-9000F 54294 SHALLCROSS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-082-1846

Technical Data | NSN 5905-01-082-1846

Characteristic Specifications
ELECTRICAL RESISTANCE 900.000 OHMS
RESISTANCE TOLERANCE IN PERCENT -1.000 TO 1.000
POWER DISSIPATION RATING IN WATTS 0.200 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 125.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 145.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -5.0 TO 5.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 145.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 48 AXIAL TERMINALS ONE END
BODY DIAMETER 0.250 INCHES NOMINAL
BODY LENGTH 0.312 INCHES NOMINAL
TERMINAL TYPE WIRE LEAD
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 1.500 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5905-01-082-1846

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-01-082-1846

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each