Product Details | THERMAL RESISTOR

5905-01-022-3928 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.

Part Alternates: DG125391J, DG125-391J, TG1/8-391-5PCT, TG183915PCT, 5905-01-022-3928, 01-022-3928, 5905010223928, 010223928

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 28 MAY 1976 01-022-3928

Drawings & Photos | NSN 5905-01-022-3928


Cross Reference | NSN 5905-01-022-3928

Part Number Cage Code Manufacturer
DG125-391J 15454 RTIE HOLDINGS LLC
TG1/8-391-5PCT 01295 TEXAS INSTRUMENTS INCORPORATED DBA TEXAS INSTRUMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-022-3928

Technical Data | NSN 5905-01-022-3928

Characteristic Specifications
ZERO POWER RESISTANCE 390.000 OHMS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -5.0 TO 5.0
MAXIMUM POWER DISSIPATION RATING 125.00 MILLIWATTS
AMBIENT TEMP AT FULL RATED POWER 100.0 DEG CELSIUS
MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS
THERMAL TIME CONSTANT IN SECONDS 60.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS 0.70
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS
STYLE DESIGNATOR 15 ROD
BODY LENGTH 0.300 INCHES MAXIMUM
BODY OUTSIDE DIAMETER 0.105 INCHES MAXIMUM
INCLOSURE TYPE HERMETICALLY SEALED
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
TERMINAL LENGTH 1.200 INCHES MINIMUM
TERMINAL DIAMETER 0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT TIN

Restrictions/Controls & Freight Information | NSN 5905-01-022-3928

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-01-022-3928

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each