Product Details | NONINDUCTIVE WIRE WOUND FIXED RESISTOR

5905-00-946-9040 INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.

Part Alternates: MILR9311, MILR93-11, RB53CE61901F, 5905-00-946-9040, 00-946-9040, 5905009469040, 009469040

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 23 MAR 1966 00-946-9040

Drawings & Photos | NSN 5905-00-946-9040


Cross Reference | NSN 5905-00-946-9040

Part Number Cage Code Manufacturer
MILR93-11 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
RB53CE61901F 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-946-9040

Technical Data | NSN 5905-00-946-9040

Characteristic Specifications
ELECTRICAL RESISTANCE 61.900 KILOHMS
RESISTANCE TOLERANCE IN PERCENT -1.000 TO 1.000
POWER DISSIPATION RATING IN WATTS 0.333 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 125.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 145.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -20.0 TO 20.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -65.0 TO 145.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 14 AXIAL TERMINAL EACH END
BODY DIAMETER 0.375 INCHES NOMINAL
BODY LENGTH 0.750 INCHES NOMINAL
TERMINAL TYPE WIRE LEAD
TEST DATA DOCUMENT 81349-MILR93/11 SPECIFICATION
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILR93-11
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE RB53CE61901F

Restrictions/Controls & Freight Information | NSN 5905-00-946-9040

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable