Product Details | ADJUSTABLE RESISTOR

5905-00-927-8519 A resistor whose overall ohmic value is fixed; in addition, it has one or more movable terminals which are designed to be set and fixed prior to use, to include any desired value of resistance within the range of the complete resistor. The opposition to the flow of current is an inherent property of the material used and is manifest in the heat dissipated in the item itself.

Part Alternates: MILR19365, RX33V750, 5905-00-927-8519, 00-927-8519, 5905009278519, 009278519

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 24 AUG 1966 00-927-8519

Drawings & Photos | NSN 5905-00-927-8519


Cross Reference | NSN 5905-00-927-8519

Part Number Cage Code Manufacturer
MILR19365 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
RX33V750 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-927-8519

Technical Data | NSN 5905-00-927-8519

Characteristic Specifications
ELECTRICAL RESISTANCE 75.000 OHMS
RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000
POWER DISSIPATION RATING IN WATTS 26.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 25.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 350.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -400.0 TO 400.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 350.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 81 RADIAL TERMINAL EACH END
BODY DIAMETER 0.593 INCHES NOMINAL
BODY LENGTH 3.000 INCHES NOMINAL
TERMINAL TYPE TAB, SOLDER LUG
RELIABILITY INDICATOR NOT ESTABLISHED
REACTANCE CHARACTERISTIC INDUCTIVE
TERMINAL LENGTH 0.329 INCHES NOMINAL
TERMINAL WIDTH 0.328 INCHES NOMINAL
TEST DATA DOCUMENT 81349-MIL-R-19365 SPECIFICATION
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILR19365
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE RX33V750

Restrictions/Controls & Freight Information | NSN 5905-00-927-8519

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5905-00-927-8519

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each