Product Details | INDUCTIVE WIRE WOUND FIXED RESISTOR

5905-00-780-7460 INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.

Part Alternates: 747-3663-00, 5905-00-780-7460, 00-780-7460, 5905007807460, 747366300, 007807460

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-780-7460

Drawings & Photos | NSN 5905-00-780-7460


Cross Reference | NSN 5905-00-780-7460

Part Number Cage Code Manufacturer
747-3663-00 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-780-7460

Technical Data | NSN 5905-00-780-7460

Characteristic Specifications
ELECTRICAL RESISTANCE 14.000 OHMS
RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000
POWER DISSIPATION RATING IN WATTS 113.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 25.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 350.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -400.0 TO 400.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 350.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 20 RADIAL TERMINAL EACH END
BODY DIAMETER 1.312 INCHES NOMINAL
BODY LENGTH 6.000 INCHES NOMINAL
TERMINAL TYPE TAB, SOLDER LUG
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 0.562 INCHES NOMINAL
TERMINAL WIDTH 0.328 INCHES NOMINAL
TEST DATA DOCUMENT 13499-747-3663-00 DRAWING

Restrictions/Controls & Freight Information | NSN 5905-00-780-7460

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-00-780-7460

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each