NSN 5905-00-357-3094 MIL-R-39005/3, MILR390053, RBR54L120R0BR
Product Details | NONINDUCTIVE WIRE WOUND FIXED RESISTOR
5905-00-357-3094 INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.
Part Alternates: MIL-R-39005/3, MILR390053, RBR54L120R0BR, 5905-00-357-3094, 00-357-3094, 5905003573094, 003573094
Electrical and Electronic Equipment Components | Resistors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 08 FEB 1974 | 00-357-3094 | 37404 ( RESISTOR, FIXED, WIRE WOUND, NONINDUCTIVE ) |
Demand History | NSN 5905-00-357-3094
Part Number | Request Date | QTY | Origin |
---|---|---|---|
MILR390053 | 2008-05-123 | 5 | United States |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5905-00-357-3094
Related Products | NSN 5905-00-357-3094
Technical Data | NSN 5905-00-357-3094
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 120.000 OHMS |
RESISTANCE TOLERANCE IN PERCENT | -0.100 TO 0.100 |
POWER DISSIPATION RATING IN WATTS | 0.250 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0 TO 10.0 |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 145.0 |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | 14 AXIAL TERMINAL EACH END |
BODY DIAMETER | 0.250 INCHES NOMINAL |
BODY LENGTH | 0.750 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
RELIABILITY INDICATOR | ESTABLISHED |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
TEST DATA DOCUMENT | 81349-MIL-R-39005 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39005/3 GOVERNMENT SPECIFICATION |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-39005/3 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RBR54L120R0BR |
Restrictions/Controls & Freight Information | NSN 5905-00-357-3094
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 062960 | REOSTATS/PARTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | P | 77.5 |
Water commodity Code | 658 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5905-00-357-3094
Category | Code | Description |
---|---|---|
Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |