Product Details | NONINDUCTIVE WIRE WOUND FIXED RESISTOR

5905-00-001-2843 INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.

Part Alternates: MIL-R-93/5, MILR935, RB18CE19703B, 5905-00-001-2843, 00-001-2843, 5905000012843, 000012843

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 22 SEP 1972 00-001-2843

Cross Reference | NSN 5905-00-001-2843

Part Number Cage Code Manufacturer
MIL-R-93/5 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
RB18CE19703B 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-001-2843

Technical Data | NSN 5905-00-001-2843

Characteristic Specifications
POWER DISSIPATION RATING IN WATTS 0.750 FREE AIR
TEST DATA DOCUMENT 81349-MIL-R-93 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 145.0
RESISTANCE TOLERANCE IN PERCENT -0.100/+0.100
RELIABILITY INDICATOR NOT ESTABLISHED
BODY LENGTH 1.250 INCHES NOMINAL
TERMINAL LENGTH 0.375 INCHES NOMINAL
TERMINAL WIDTH 0.188 INCHES NOMINAL
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 125.0
TERMINAL TYPE TAB, SOLDER LUG
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -20.0/+20.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -65.0/+145.0
STYLE DESIGNATOR RADIAL TERMINAL EACH END
BODY DIAMETER 0.750 INCHES NOMINAL
ELECTRICAL RESISTANCE 1.970 MEGOHMS
SPECIFICATION/STANDARD DATA 81349-MIL-R-93/5 GOVERNMENT SPECIFICATION
INCLOSURE METHOD ENCAPSULATED

Restrictions/Controls & Freight Information | NSN 5905-00-001-2843

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable