Product Details | POWER FREQUENCY DIVIDER-COMBINER

5895-01-605-7394 An item which has the dual functions of a FREQUENCY DIVIDER and a MIXER STAGE, FREQUENCY. The item combines the inputs of two or more signals into a single signal or group of signals, and also has the characteristic of dividing signals into predetermined proportional signals.

Part Alternates: ZMSC22, ZMSC-2-2, 5895-01-605-7394, 01-605-7394, 5895016057394, 016057394

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 24 APR 2012 01-605-7394

Cross Reference | NSN 5895-01-605-7394

Part Number Cage Code Manufacturer
ZMSC-2-2 387H4 SCIENTIFIC COMPONENTS DBA MINI CIRCUITS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-605-7394

Technical Data | NSN 5895-01-605-7394

Characteristic Specifications
OVERALL LENGTH 1.500 INCHES NOMINAL
CIRCUIT CONSTRUCTION TYPE SOLID STATE
OPERATING TEMP RANGE -55.0 TO 100.0 DEG CELSIUS
FREQUENCY PER CHANNEL 60.0 MEGAHERTZ MAXIMUM INPUT CHANNEL
OVERALL HEIGHT 1.130 INCHES NOMINAL
BASIC SHAPE STYLE RECTANGULAR OR SQUARE
INCLOSURE TYPE ENCASED
CONNECTION TYPE AND LOCATION INTEGRAL CABLE W/COAXIAL PLUG FRONT
OVERALL WIDTH 1.000 INCHES NOMINAL
SPECIAL FEATURES POWER INPUT(AS A SPLITTER)1W MAX,INTERNAL DISSIPATION:0.125W MAX,COAXIALCONNECTIONS:SUM PORT 2,PORT1-1,PORT2-3,WIDEBAND:0.002 TO 60MHZ,LOW INSERTION LOSS:0.3DB TYP,GOOD ISOLATION:30DB TYP,AMPLITUDE UNBALANCE:0.1DB TYP,PHASE UNBALANCE:0.2 DEG.TYP,RUGGED SHIELDER CASE,STORAGE TEMPERATURE:-55 DEGREES TO 100 DEGREES CELSIUS,OPERATING TEMPERATURE:-55 DEGREES TO 100.0 DEGREES CELSIUS

Restrictions/Controls & Freight Information | NSN 5895-01-605-7394

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information