Product Details | STATIC FREQUENCY CONVERTER

5895-01-572-4223 An item utilizing electron tubes, transistors, and/or semiconductor devices forming rectifier and electronic keying or switching circuitry, that is inserted between a load designed to operate at one frequency and a power supply line rated at another frequency. For items performing the same function by heterodyne action at either radio or power line frequencies, see CONVERTER, FREQUENCY, ELECTRONIC. For items that perform this function by means of rotary equipment, see MOTOR-GENERATOR. See also DIVIDER-MULTIPLIER, FREQUENCY; FREQUENCY DIVIDER; FREQUENCY MULTIPLIER and MIXER STAGE, FREQUENCY.20358950037Miscellaneous Communication Equipment59630018Electronic Modules61300035Converters, Electrical, Nonrotating

Part Alternates: SPC610003PH, SPC6-1000-3PH, 5895-01-572-4223, 01-572-4223, 5895015724223, 015724223

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 11 MAR 2009 01-572-4223

Cross Reference | NSN 5895-01-572-4223

Part Number Cage Code Manufacturer
SPC6-1000-3PH 51Z16 KGS ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-572-4223

Technical Data | NSN 5895-01-572-4223

Characteristic Specifications
OUTPUT FREQUENCY RATING 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM
INPUT FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
HEIGHT 7.000 INCHES NOMINAL
MOUNTING METHOD RACK
USAGE DESIGN FOR USE ON TEST BENCHES TO CHECK RADARS, COMPASSES, GYROS, SYNCHROS OR ANY INSTRUMENT REQUIRING 3 PHASE POWER
PHASE THREE
PART NAME ASSIGNED BY CONTROLLING AGENCY FREQUENCY CHANGER
COOLING METHOD INTEGRAL FAN
INPUT PHASE SINGLE
LENGTH 17.000 INCHES NOMINAL
WIDTH 13.000 INCHES NOMINAL
SPECIAL FEATURES SOLID STATE; CONVERTS 115 VAC 50/60 HZ. TO 115/200 VAC AND 26/45 VAC, 400 HZ. 3 PHASE SINE WAVE POWER
AC INPUT VOLTAGE RATING 115.0 VOLTS NOMINAL

Restrictions/Controls & Freight Information | NSN 5895-01-572-4223

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information