Product Details | SIGNAL DATA RECORDER

5895-01-469-9111 An item which makes a permanent representation of electronic signal data derived from target parameters, guidance and evaluation signals, and the like, These signals may be above or below 20,000 hertz. They may be in digital and/or analog form, the characteristics of which limits useful playback to a compatable reproducer. These items usually include multichannel signal input facilities for the simultaneous recording of several types of signals. Excludes RECORDER, SOUND.20258950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: VR204, 5895-01-469-9111, 01-469-9111, 5895014699111, 014699111

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 30 NOV 1999 01-469-9111

Cross Reference | NSN 5895-01-469-9111

Part Number Cage Code Manufacturer
VR204 62264 EVENTIDE INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-469-9111

Technical Data | NSN 5895-01-469-9111

Characteristic Specifications
RECORDING METHOD TAPE
INFORMATION RECORDED AUDIO COMMUNICATIONS
CHANNEL QUANTITY 4
TOTAL CHANNEL QUANTITY 4
AC VOLTAGE RATING 100.0 VOLTS NOMINAL AND 230.0 VOLTS MAXIMUM
OVERALL WIDTH 14.600 INCHES NOMINAL
OVERALL HEIGHT 3.500 INCHES NOMINAL
OVERALL DEPTH 9.000 INCHES NOMINAL
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME DIGITAL COMMUNICATIONS LOGGER
SPECIAL FEATURES CAN RECORD AND PLAY UP TO 550 HOURS; LOGS PHONE CALLS, TWO-WAY RADIO COMMUNICATIONS AND BROADCASTS; EQUIPPED WITH HARD DISK MEMORY MODULE

Restrictions/Controls & Freight Information | NSN 5895-01-469-9111

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information