Product Details | VIDEO SIGNAL DETECTOR

5895-01-431-7052 An electronic device which demodulates video signals. It is used with equipment in which electrical impulses are converted into visual presentations on the screen of a cathode ray tube.20458400032Radar Equipment, Except Airborne58950037Miscellaneous Communication Equipment59630018Electronic Modules66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: MA7709A0185P, MA7709A-0185P, 2338651, 233865-1, 5895-01-431-7052, 01-431-7052, 5895014317052, 014317052

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 16 MAY 1996 01-431-7052

Drawings & Photos | NSN 5895-01-431-7052


Cross Reference | NSN 5895-01-431-7052

Part Number Cage Code Manufacturer
233865-1 94987 CUBIC DEFENSE APPLICATIONS, INC.
MA7709A-0185P 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-431-7052

Technical Data | NSN 5895-01-431-7052

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
INDIVIDUAL SECTION QUANTITY 1
OPERATING CONTROL METHOD AUTOMATIC
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 2 CYLINDRICAL
OVERALL LENGTH 1.280 INCHES MINIMUM AND 1.460 INCHES MAXIMUM
OVERALL DIAMETER 0.295 INCHES MINIMUM AND 0.330 INCHES MAXIMUM
SPECIAL FEATURES ELECTRO-STATIC SENSITIVE
RELIABILITY INDICATOR NOT ESTABLISHED
III FRAGILITY FACTOR MODERATELY RUGGED

Restrictions/Controls & Freight Information | NSN 5895-01-431-7052

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5895-01-431-7052

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Materiel Management Aggregation CodeTGTG:AF SICA RESIDUAL MMAC-WR-ALC
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative