NSN 5895-01-352-1306 627500G03, 01-352-1306, 013521306
Product Details | ELECTRONIC FREQUENCY CONVERTER
5895-01-352-1306 An electronic device having frequency mixing circuits and an integral oscillator which mixes the incoming frequency(ies) with the oscillator frequency, the resultant frequency(ies) being a combination of the two sources. Includes equipment that performs these functions at either radio or power line frequencies. Excludes items that change frequency by means of rotating equipment or rectifier and switching or keying circuitry.20358950037Miscellaneous Communication Equipment59630018Electronic Modules61300035Converters, Electrical, Nonrotating
Part Alternates: 627500G03, 5895-01-352-1306, 01-352-1306, 5895013521306, 013521306
Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 20 JAN 1992 | 01-352-1306 | 00329 ( CONVERTER, FREQUENCY, ELECTRONIC ) |
Cross Reference | NSN 5895-01-352-1306
Part Number | Cage Code | Manufacturer |
---|---|---|
627500G03 | 91417 | HARRIS CORPORATION DBA GOVERNMENT COMMUNICATIONS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5895-01-352-1306
Related Products | NSN 5895-01-352-1306
Technical Data | NSN 5895-01-352-1306
Characteristic | Specifications |
---|---|
CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
III END ITEM IDENTIFICATION | ACFT MODEL F14-A |
MANUFACTURERS CODE | 91417 |
DESIGN CONTROL REFERENCE | 627500G03 |
Restrictions/Controls & Freight Information | NSN 5895-01-352-1306
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | P | Munitions List Item. Demilitarization required. Security classified item - Declassification and any additional demilitarization and removal of any sensitive markings or information will be accomplished prior to accountability or physical transfer to a DRMO. This code will not be assigned to AEDA items. |
Controlled Inventory Item Code: | C | CONFIDENTIAL OR MODERATE SENSITIVITY (SRC III) AND LOW SENSITIVITY (SRC IV) - CONFIDENTIAL AA&E. (ITEM WILL BE STORED AND TRANSPORTED IN ACCORDANCE WITH THE PROVISIONS OF DOD 5100.76M OR DOD 5200.1R INFORMATION SECURITY PROGRAM - WHICHEVER IS MORE STRINGENT)./ |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | W | Rating Variable |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | ||
Air Special Handling | Y | Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions. |
Special Handling Code | 2 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5895-01-352-1306
Category | Code | Description |
---|---|---|
Cognizance Codes | 7R | Aeronautical Depot Level Repairable Spares Naval Inventory Control Point, Philadelphia |
Special Material ID | PF | FIGHTERAIRCRAFT(F14) |
Issue Repair, or Requisition | CF | Fleet Control Program Items. Submit/refer requisitions to NAVICP PHIL following standard procedures. |
Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | H | Depot Level Reparable |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | C | CONFIDENTIAL OR MODERATE SENSITIVITY (SRC III) AND LOW SENSITIVITY (SRC IV) - CONFIDENTIAL AA&E. (ITEM WILL BE STORED AND TRANSPORTED IN ACCORDANCE WITH THE PROVISIONS OF DOD 5100.76M OR DOD 5200.1R INFORMATION SECURITY PROGRAM - WHICHEVER IS MORE STRINGENT). |
Shelf Life Code | 0 | Nondeteriorative |