Product Details | CONTROL-INDICATOR

5895-01-266-0949 A component which performs the dual function of presenting visual information from other sources such as navigation, radar and the like and regulating the mode of operation of those sources. This item is essential to the end use or operation of the other sources. See also CONTROL-MONITOR.20258950037Miscellaneous Communication Equipment66050024Navigational Instruments

Part Alternates: C-11153/ALT-40, C11153ALT40, 78E6N1500, 5895-01-266-0949, 01-266-0949, 5895012660949, 012660949

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 20 OCT 1987 01-266-0949

Cross Reference | NSN 5895-01-266-0949

Part Number Cage Code Manufacturer
78E6N1500 28687 NAVY, UNITED STATES DEPARTMENT OF THE SPAWAR DBA SPACE AND NAVAL
C-11153/ALT-40 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-266-0949

Technical Data | NSN 5895-01-266-0949

Characteristic Specifications
POWER SOURCE EXTERNAL
TERMINAL TYPE AND QUANTITY 2 CONNECTOR, RECEPTACLE
TERMINAL LOCATION BACK
CONNECTOR MANUFACTURER PART NUMBER MS27505E15835P AND MS27505E11898P
CONNECTOR MANUFACTURER CODE 81349 AND 81349
INCLOSURE TYPE ENCASED
III END ITEM IDENTIFICATION COUNTERMEASURES SET AN/ALT-40
III FSC APPLICATION DATA AIRBORNE COUNTERMEASURES
MANUFACTURERS CODE 28687
DESIGN CONTROL REFERENCE 78E6N1500

Restrictions/Controls & Freight Information | NSN 5895-01-266-0949

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5895-01-266-0949

Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDEWFleet Electronic Warfare Support Group
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative