NSN 5895-01-154-7516 WJ530071, WJ-5300-71, 172AS507
Product Details | LOW-NOISE AMPLIFIER
5895-01-154-7516
Part Alternates: WJ530071, WJ-5300-71, 172AS507, 5895-01-154-7516, 01-154-7516, 5895011547516, 011547516
Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 30 MAY 1983 | 01-154-7516 | 77777 ( ) |
Demand History | NSN 5895-01-154-7516
Part Number | Request Date | QTY | Origin |
---|---|---|---|
172AS507 | 2008-10-305 | 4 | US |
Cross Reference | NSN 5895-01-154-7516
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5895-01-154-7516
Related Products | NSN 5895-01-154-7516
Technical Data | NSN 5895-01-154-7516
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | FREQUENCY RANGE 4 TO 8 GHZ; INPUT AND OUTPUT IMPEDANCE: 50 OHMS NOMINAL; POWER 115 VAC; 6 WATTS DISSIPATION; 4.500 IN. LG. MAX; 3.140 IN. W. MAX; 2.520 IN. H; 6 HOLES 0.188 DIA |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY THE SOURCE CONTROL DWG NO. |
MANUFACTURERS CODE | 30003 |
MFR SOURCE CONTROLLING REFERENCE | 172AS507 |
MANUFACTURERS CODE | 14482 |
DESIGN CONTROL REFERENCE | WJ-5300-71 |
Restrictions/Controls & Freight Information | NSN 5895-01-154-7516
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063035 | SETS RADIO/TV AND RELATED ARTICLES |
Less than car load rating | G | 125 |
Less than truck load rating | G | 125.0 |
Water commodity Code | 758 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | ||
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5895-01-154-7516
Category | Code | Description |
---|---|---|
Cognizance Codes | 7R | Aeronautical Depot Level Repairable Spares Naval Inventory Control Point, Philadelphia |
Special Material ID | EP | PATROLAIRCRAFT(EP-3E) |
Issue Repair, or Requisition | AR | Repairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved. |
Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | H | Depot Level Reparable |
Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |