5895-01-139-7385 An indicator that displays data for the determination of the terrestrial bearing, vertical spacing, and range, or spacing, between a target and a common reference point, as determined by interpolation.20312900036Miscellaneous Fire Control Equipment14300037Guided Missile Remote Control Systems58400032Radar Equipment, Except Airborne

Part Alternates: IP-1060A/APQ-148, IP1060AAPQ148, 212083000101, 2120-83000-101, 5895-01-139-7385, 01-139-7385, 5895011397385, 011397385

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 05 OCT 1982 01-139-7385

Cross Reference | NSN 5895-01-139-7385

Part Number Cage Code Manufacturer
2120-83000-101 95542 NORTHROP GRUMMAN SYSTEMS CORPORATION
IP-1060A/APQ-148 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-139-7385

Technical Data | NSN 5895-01-139-7385

Characteristic Specifications
PRESENTATION TYPE CATHODE RAY TUBE
DC VOLTAGE RATING 28.0 VOLTS NOMINAL
AC VOLTAGE RATING 115.0 VOLTS MINIMUM AND 200.0 VOLTS MAXIMUM
PHASE THREE
FREQUENCY RATING 400.0 HERTZ NOMINAL
LENGTH 23.700 INCHES NOMINAL
WIDTH 8.600 INCHES NOMINAL
HEIGHT 9.800 INCHES NOMINAL
MANUFACTURERS CODE 95542
DESIGN CONTROL REFERENCE 2120-83000-101

Restrictions/Controls & Freight Information | NSN 5895-01-139-7385

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating W Rating Variable
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5895-01-139-7385

Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDLAATTACKAIRCRAFT(EA-6B)
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityE(1) IRAM Program Intensive Management Reparables (2) Material (expendable ordnance) Requiring Lot and Serial Number Control but which is Reported by Serial Number Only
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative