Product Details | ELECTRONIC FREQUENCY CONVERTER

5895-01-033-9864 An electronic device having frequency mixing circuits and an integral oscillator which mixes the incoming frequency(ies) with the oscillator frequency, the resultant frequency(ies) being a combination of the two sources. Includes equipment that performs these functions at either radio or power line frequencies. Excludes items that change frequency by means of rotating equipment or rectifier and switching or keying circuitry.20358950037Miscellaneous Communication Equipment59630018Electronic Modules61300035Converters, Electrical, Nonrotating

Part Alternates: 727-006-001, MT4, 5895-01-033-9864, 01-033-9864, 5895010339864, 727006001, 010339864

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 15 JAN 1977 01-033-9864

Drawings & Photos | NSN 5895-01-033-9864


Cross Reference | NSN 5895-01-033-9864

Part Number Cage Code Manufacturer
727-006-001 17903 ANDREW SCICOMM INC
MT4 17903 ANDREW SCICOMM INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-033-9864

Technical Data | NSN 5895-01-033-9864

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 100.0 MEGAHERTZ NOMINAL OPERATING CHANNEL 60.0 MEGAHERTZ NOMINAL INPUT CHANNEL 160.0 MEGAHERTZ NOMINAL OUTPUT CHANNEL
INDIVIDUAL SECTION QUANTITY 3
ATTENUATION IN DECIBELS 8.5
AVERAGE POWER RATING PER CHANNEL NOT RATED
SIGNAL VOLTAGE RATING PER CHANNEL NOT RATED
OVERALL GAIN NOT RATED
IMPEDANCE RATING PER CHANNEL 50.000 OHMS OPERATING CHANNEL 50.000 OHMS INPUT CHANNEL 50.000 OHMS OUTPUT CHANNEL
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING NOT RATED
OPERATING TEMP RANGE NOT RATED
VIBRATION RESISTANCE RANGE IN HERTZ NOT RATED
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS NOT RATED
CONNECTION TYPE AND LOCATION PRINTED CIRCUIT BOTTOM
CONNECTION CONTACT TYPE AND QUANTITY 8 PRINTED CIRCUIT EXTERNAL
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN MODULE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 0.900 INCHES MAXIMUM
OVERALL HEIGHT 0.750 INCHES MAXIMUM
OVERALL WIDTH 0.450 INCHES MAXIMUM
IDENTIFICATION DESIGNATOR 727-006-001-17903

Restrictions/Controls & Freight Information | NSN 5895-01-033-9864

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 116030 MACHINES ETC DATA PROCESSING
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5895-01-033-9864

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative