Product Details | AMPLIFIER-POWER SUPPLY

5895-00-857-0774 A component having the dual function of a power supply and an amplifier. The power supply and amplifier are used with associated components and may be used with each other. May include accessories.

Part Alternates: AM3320FPS82, 06510691, 0651069-1, 5895-00-857-0774, 00-857-0774, 5895008570774, 008570774

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 01 JAN 1960 00-857-0774

Cross Reference | NSN 5895-00-857-0774

Part Number Cage Code Manufacturer
0651069-1 06845 RAYTHEON COMPANY DBA RAYTHEON
AM3320FPS82 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-00-857-0774

Technical Data | NSN 5895-00-857-0774

Characteristic Specifications
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
AC VOLTAGE RATING 110.0 VOLTS NOMINAL
FREQUENCY RATING 60.0 HERTZ NOMINAL
PHASE SINGLE
OVERALL LENGTH 12.000 INCHES NOMINAL
OVERALL WIDTH 14.000 INCHES NOMINAL
OVERALL HEIGHT 18.000 INCHES NOMINAL
AMPLIFIER NAME ELECTRONIC CONTROL AMPLIFIER
AMPLIFIER POWER OUTPUT RATING 65.0 WATTS NOMINAL
AMPLIFIER OUTPUT IMPEDANCE RATING 4.8 KILOHMS NOMINAL
POWER SUPPLY OUTPUT CURRENT TYPE DC
POWER SUPPLY OUTPUT VOLTAGE RATING 450.0 VOLTS NOMINAL 250.0 VOLTS NOMINAL -40.0 VOLTS NOMINAL
POWER SUPPLY OUTPUT CURRENT RATING 100.0 MILLIAMPERES NOMINAL 40.0 MILLIAMPERES NOMINAL 10.0 MILLIAMPERES NOMINAL
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME AMPLIFIER-POWER SUPPLY
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER AM-3320/FPS-82
III FSC APPLICATION DATA RADAR SET,NONAIRBORNE,EXCEPT FIRE CONTROL AND GUIDED MISSILE
MANUFACTURERS CODE 06845
DESIGN CONTROL REFERENCE 0651069-1

Restrictions/Controls & Freight Information | NSN 5895-00-857-0774

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:CMunitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating
Less than truck load rating G 125.0
Water commodity Code 723 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5895-00-857-0774

Category Code Description
Cognizance Codes3BNavy-owned stocks of field level repairable DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each