Product Details | ELECTRONIC FREQUENCY CONVERTER

5895-00-135-1638 An electronic device having frequency mixing circuits and an integral oscillator which mixes the incoming frequency(ies) with the oscillator frequency, the resultant frequency(ies) being a combination of the two sources. Includes equipment that performs these functions at either radio or power line frequencies. Excludes items that change frequency by means of rotating equipment or rectifier and switching or keying circuitry.20358950037Miscellaneous Communication Equipment59630018Electronic Modules61300035Converters, Electrical, Nonrotating

Part Alternates: CV221, 5895-00-135-1638, 00-135-1638, 5895001351638, 001351638

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 16 NOV 1973 00-135-1638

Drawings & Photos | NSN 5895-00-135-1638


Cross Reference | NSN 5895-00-135-1638

Part Number Cage Code Manufacturer
CV221 51283 TECHNICAL SERVICES LABORATORY, INC. DBA TSL-REICO
CV221 60590 AIKEN ADVANCED SYSTEMS INC A DIV OF AMSTAR TECHNICAL PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-00-135-1638

Technical Data | NSN 5895-00-135-1638

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 21.4 MEGAHERTZ MINIMUM OPERATING CHANNEL 60.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
OVERALL GAIN 40.0 DECIBELS
INCLOSURE TYPE ENCASED
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
III FSC APPLICATION DATA RECEIVER,COUNTERMESURES SET
MANUFACTURERS CODE 51283
DESIGN CONTROL REFERENCE CV221

Restrictions/Controls & Freight Information | NSN 5895-00-135-1638

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating W Rating Variable
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5895-00-135-1638

Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDEPPATROLAIRCRAFT(EP-3E)
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplyN32Naval Inventory Control Point
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each