5895-00-123-2198 An electronic device whose input signals control power from a source independent of the input signals and delivers output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It is used for small variations in direct current electrical impulses, and generally employs direct coupling between stages through resistors.
Part Alternates: 001232198
Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 00-123-2198 | 19692 ( AMPLIFIER, DIRECT CURRENT ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5895-00-123-2198
Related Products | NSN 5895-00-123-2198
Technical Data | NSN 5895-00-123-2198
Characteristic | Specifications |
---|---|
ATTENUATION IN DECIBELS | NOT RATED |
AVERAGE POWER RATING PER CHANNEL | 10.0 WATTS OUTPUT |
SIGNAL VOLTAGE RATING PER CHANNEL | NOT RATED |
OVERALL GAIN | NOT RATED |
IMPEDANCE RATING PER CHANNEL | 1.000 MEGOHMS INPUT CHANNEL 100.000 OHMS OUTPUT CHANNEL |
PULSE PEAK AMPLITUDE PER CHANNEL | NOT RATED |
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
OPERATING TEMP RANGE | NOT RATED |
VIBRATION RESISTANCE RANGE IN HERTZ | NOT RATED |
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | NOT RATED |
EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 9.0 NOMINAL 1ST VOLTAGE 20.0 NOMINAL 2ND VOLTAGE 28.0 NOMINAL 3RD VOLTAGE |
BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
OVERALL LENGTH | 5.250 INCHES NOMINAL |
OVERALL HEIGHT | 0.635 INCHES NOMINAL |
OVERALL WIDTH | 1.750 INCHES NOMINAL |
III FSC APPLICATION DATA | TRANSLATOR,RADIO,COMMUNICATION,AI RBORNE |
MANUFACTURERS CODE | 13499 |
DESIGN CONTROL REFERENCE | 778-2595-001 |
Restrictions/Controls & Freight Information | NSN 5895-00-123-2198
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Category | Code | Description |
---|---|---|
No Freight Information |