NSN 5865-00-301-2985 15B0049, 15C0049, 20C23371
Product Details | IMAGE PHASE MIXER
5865-00-301-2985
Part Alternates: 15B0049, 15C0049, 20C23371, 20C2337-1, 20C23372, 20C2337-2, 5865-00-301-2985, 00-301-2985, 5865003012985, 003012985
Communication, Detection, and Coherent Radiation Equipment | Electronic Countermeasures, Counter-Countermeasures and Quick Reaction Capability Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 03 OCT 1973 | 00-301-2985 | 77777 ( ) |
Demand History | NSN 5865-00-301-2985
Part Number | Request Date | QTY | Origin |
---|---|---|---|
20C2337-2 | 2019-06-180 | 3 | |
20C2337-2 | 2018-11-306 | 5 |
Cross Reference | NSN 5865-00-301-2985
Part Number | Cage Code | Manufacturer |
---|---|---|
15B0049 | 31597 | ANAREN, INC. DIV ANAREN MICROWAVE, INC. |
15C0049 | 31597 | ANAREN, INC. DIV ANAREN MICROWAVE, INC. |
20C2337-1 | 92755 | NORTHROP GRUMMAN SYSTEMS CORPORATION DBA LAND & SELF PROTECTION SYSTEM |
20C2337-2 | 92755 | NORTHROP GRUMMAN SYSTEMS CORPORATION DBA LAND & SELF PROTECTION SYSTEM |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5865-00-301-2985
Related Products | NSN 5865-00-301-2985
Technical Data | NSN 5865-00-301-2985
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | IMAGE PHASING MIXER DUAL CHANNEL BAND 4; MAX WGT 9.3 OZ MAX;E/I E-2C ACFT |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SOURCE CONTROL DRAWING NUMBER |
MANUFACTURERS CODE | 92755 |
MFR SOURCE CONTROLLING REFERENCE | 20C2337-2 |
MANUFACTURERS CODE | 92755 |
DESIGN CONTROL REFERENCE | 20C2337-1 |
Restrictions/Controls & Freight Information | NSN 5865-00-301-2985
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | W | Rating Variable |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | ||
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5865-00-301-2985
Category | Code | Description |
---|---|---|
Cognizance Codes | 7R | Aeronautical Depot Level Repairable Spares Naval Inventory Control Point, Philadelphia |
Special Material ID | EE | SPECIAL ELECTRONICAIRCRAFT(E2C) |
Issue Repair, or Requisition | AR | Repairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved. |
Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | H | Depot Level Reparable |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |